Professional testing equipment and reports to ensure product quality.
ELECTRONIC COMPONENTS

Humidity, Moisture Sensors

Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status Sensor Type Humidity Range Output Type Output Accuracy Response Time Sensitivity Voltage - Supply Mounting Type Operating Temperature Grade Qualification Supplier Device Package
A/RH1-O-NIST Automation Components, Inc.

A/RH1-O-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

3,365 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount 1.5°C ~ 60°C - - Module
A/RH1-20K-D-NIST Automation Components, Inc.

A/RH1-20K-D-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

2,314 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH1-1K-NI-D-NIST Automation Components, Inc.

A/RH1-1K-NI-D-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

4,475 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH1-CP-D-NIST Automation Components, Inc.

A/RH1-CP-D-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

2,432 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -25°C ~ 60°C - - -
A/RH1-100-3W-D-NIST Automation Components, Inc.

A/RH1-100-3W-D-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1,739 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH1-D-BB-NIST Automation Components, Inc.

A/RH1-D-BB-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

4,396 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -25°C ~ 60°C - - -
A/RH2-O-SUN Automation Components, Inc.

A/RH2-O-SUN

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

3,765 -
Datasheet - Module Tape & Box (TB) Active Humidity 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH3-1K-2W-RP2-10'-EH Automation Components, Inc.

A/RH3-1K-2W-RP2-10'-EH

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

4,638 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±3% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -25°C ~ 60°C - - -
A/RH1-TT1K-R-4 Automation Components, Inc.

A/RH1-TT1K-R-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

2,895 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH1-TT1K-R2-2 Automation Components, Inc.

A/RH1-TT1K-R2-2

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

3,563 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Voltage 2V ~ 10V ±1% RH 20 s - 18 ~ 28VAC, 18 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH1-TT1K-R2-4 Automation Components, Inc.

A/RH1-TT1K-R2-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

4,129 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH2-RP2-10'-EH Automation Components, Inc.

A/RH2-RP2-10'-EH

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

4,957 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -25°C ~ 60°C - - -
A/RH1-TT100-R2-4 Automation Components, Inc.

A/RH1-TT100-R2-4

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

3,401 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 15 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH1-1K-NI-O-NIST Automation Components, Inc.

A/RH1-1K-NI-O-NIST

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1,131 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±1% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - Module
A/RH1-TT1K-R-2 Automation Components, Inc.

A/RH1-TT1K-R-2

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

2,453 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Voltage 2V ~ 10V ±1% RH 20 s - 18 ~ 28VAC, 18 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH2-1K-2W-O-SUN Automation Components, Inc.

A/RH2-1K-2W-O-SUN

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

3,871 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH2-1.8K-O-SUN Automation Components, Inc.

A/RH2-1.8K-O-SUN

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

2,999 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH2-1K-NI-O-SUN Automation Components, Inc.

A/RH2-1K-NI-O-SUN

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

2,381 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH2-20K-O-SUN Automation Components, Inc.

A/RH2-20K-O-SUN

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1,907 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
A/RH2-CSI-O-SUN Automation Components, Inc.

A/RH2-CSI-O-SUN

Relative Humidity, RH Outputs: 0

Automation Components, Inc.

1,394 -
Datasheet - Module Tape & Box (TB) Active Humidity, Temperature 0 ~ 100% RH Analog Current, Analog Voltage 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA ±2% RH 20 s - 18 ~ 28VAC, 12 ~ 40VDC Chassis Mount -40°C ~ 60°C - - -
Total 1335 Record«Prev1... 6061626364656667Next»
BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Humidity, Moisture Sensors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.