1 ISREFH Reference Input for Current Sense Amplifier - Connect to VREF to shift output by 12.5 mV[reference:35]
2 ISREFL Reference Input for Current Sense Amplifier - Default connection to ground[reference:36]
3 ISREFLS Test Kelvin Sense Pin for ISREFL[reference:37]
4 ISVP Current Sense In-Amp Positive Input - High side of current sense shunt[reference:38]
5 ISVN Current Sense In-Amp Negative Input - Low side of current sense shunt[reference:39]
6 BVP Battery Voltage Diff-Amp Positive Input[reference:40]
7 BVPS Test Kelvin Sense Pin for BVP[reference:41]
8 BVN Battery Voltage Diff-Amp Negative Input[reference:42]
9 BVNS Test Kelvin Sense Pin for BVN[reference:43]
10 BVREFL Reference Input for Voltage Sense Diff-Amp - Default connection to ground[reference:44]
11 BVREFLS Test Kelvin Sense Pin for BVREFL[reference:45]
12 BVREFH Reference Input for Diff-Amp - Connect to VREF to level shift BVMEA[reference:46]
13 AVEE Analog Negative Supply Pin[reference:47]
14 VSET Scaled CV Loop Control Input for Battery Charge or Discharge Cycle[reference:48]
15 VVP0 Noninverting CV Loop Filter Amplifier Input for Discharge Mode[reference:49]
16 BVMEA Scaled Battery Voltage - Difference Amplifier Output[reference:50]
17 VSETB Buffered VSET Voltage[reference:51]
18 VVE0 Inverting Input of CV Loop Filter Amplifier - Discharge Mode[reference:52]
19 VVE1 Inverting Input of CV Loop Filter Amplifier - Charge Mode[reference:53]
20 VINT Aggregated Result of Battery Voltage and Current Sense Integration[reference:54]
21 AVEE Analog Negative Supply Pin[reference:55]
22 MODE Logic Input - High for Charge, Low for Discharge Mode[reference:56]
23 EN Logic Enable Input - Low shuts down, High turns on device[reference:57]
24 FAULT External Fault Comparator Connection - Disables DH/DL when low[reference:58]
25 CLFLG Current-Limit Flag - Open-drain, active low output[reference:59]
26 SYNC Clock Synchronization I/O - For phase interleaving multiple channels[reference:60]
27 SCFG Synchronization Configuration Pin[reference:61]
28 VREG Internal 5V LDO Regulator Output - Bypass with 1 µF capacitor[reference:62]
29 VIN PWM Section Supply Voltage - Typically same as output switch supply[reference:63]
30 DL Logic Drive Output for External Low-Side MOSFET Driver[reference:64]
31 DH Logic Drive Output for External High-Side MOSFET Driver[reference:65]
32 DGND Digital and PWM Ground[reference:66]
33 DT Dead Time Programming - External resistor to ground[reference:67]
34 SS Soft Start Control - Capacitor to ground sets ramp time[reference:68]
35 DMAX Maximum Duty Cycle Input - Resistor to ground sets DMAX[reference:69]
36 FREQ Frequency Set - Resistor to ground sets 50–300 kHz[reference:70]
37 CLVT Current-Limit Voltage Threshold - User selected resistor[reference:71]
38 CLP Current-Limit/Diode Emulation Amplifier Positive Sense[reference:72]
39 CLN Current-Limit/Diode Emulation Amplifier Negative Sense[reference:73]
40 AVCC Analog Positive Supply Pin[reference:74]
41 VINT Aggregated Result of Battery Voltage and Current Sense Integration[reference:75]
42 IVE1 Inverting Input of CC Loop Filter Amplifier - Charge Mode[reference:76]
43 IVE0 Inverting Input of CC Loop Filter Amplifier - Discharge Mode[reference:77]
44 ISMEA Current Sense Instrumentation Amplifier Output[reference:78]
45 ISET Scaled CC Voltage Loop Control Input[reference:79]
46 AVCC Analog Positive Supply Pin[reference:80]
47 AGND Analog Ground[reference:81]
48 VREF 2.5 V Reference Output - Bypass with 10 nF NP0 + 10 Ω series resistor[reference:82]